A 3-ply roof underlayment membrane with high resistance to wear, temperature exposure, driving rain, and includes (2) integrated self-adhesive strips.
Size: 4'11" (1.5 m) x 164' (50 m)
|
| |
Protective and covering fleece | Polypropylene microfibre | |
Functional film | Monolithic TEEE | |
Property | Regulation | Value |
Colour | Anthracite | |
Surface weight | EN 1849-2 | 150 g/m²; 0.5 oz/ft² |
Thickness | EN 1849-2 | 0.45 mm ; 18 mils |
Water vapour resistance factor µ | EN ISO 12572 | 110 |
sd value | EN ISO 12572 | 0.05 m |
g value | 0.25 MN·s/g | |
Vapour permeance | ASTM E 96 | 38 perms |
Fire class | EN 13501-1 | E |
Outdoor exposure | 4 months | |
Hail impact resistance | VKF / AEAI | Class HR 5 |
Watertight joints with ‘connect’ adhesive strips or TESCON VANA tape | EN 13859-1 | W1 |
Sarking/roofing underlay membrane (Germany) | ZVDH-Produktdatenblatt 2024 | USB / UDB |
Suitable as temporary roof covering (Germany) | ZVDH | Yes |
Water column | EN ISO 811 | 10 000 mm ; 32' 10" |
Watertightness, non-aged/aged* | EN 13859-1 | W1 / W1 |
Tensile strength MD/CD | EN 13859-1 (A) | 280 N/5 cm / 220 N/5 cm ; 32 lb/in / 25 lb/in |
Tensile strength MD/CD, aged* | EN 13859-1 (A) | 240 N/5 cm / 165 N/5 cm ; 27 lb/in / 19 lb/in |
Elongation MD/CD | EN 13859-1 (A) | 60% / 70% |
Elongation MD/CD, aged* | EN 13859-1 (A) | 50% / 65% |
Nail tear resistance MD/CD | EN 13859-1 (B) | 180 N / 230 N ; 40 lbf / 52 lbf |
*) Durability after artificial ageing at 120 °C ; 248 °F | EN 1297 / EN 1296 | Passed |
Flexibility at low temperature | EN 1109 | -40 °C ; -40 °F |
Temperature resistance | EN 1109, EN 1296, EN 1297 | permanent -40 °C to +120 °C; -40 °F to 248 °F |
Thermal conductivity | 0.04 W/(m·K) ; 0.3 BTU·in/(h·ft²·°F) | |
CE labelling | EN 13859-1 | Yes |